basic assembly standards

STATIC LOAD/WEIGHT

The static load limit is 3,500kg/m², and the measurements of Gate C1 are 7m (width) x 6m (height) and Gate C2 are 7m (width) x 4 (height).

 

MAXIMUM PERMITTED HEIGHT/SETBACK (CLEARANCE)

The maximum height allowed for a stand is 5m from the pavilion floor. Only for stands with a mezzanine floor is the maximum height 5m. Stands under the pavilion mezzanine must have a maximum height of 3.2m from the floor. Exhibitor's products must be contained within this height. Above 2.2m, the wall facing the neighbor must be finished with material compatible with that of the stand, without any advertising. Stands higher than 3.5m from the pavilion floor must be set back from the neighboring stand. The entire length of the stand must be set back. A beveled indentation will not be accepted.

ISLANDS, ISLAND TIPS OR CORNERS

Under no circumstances may stands be completely closed off from traffic. The closure limit is 30% of the linear footage on each side of the stand (maximum height 5m). Stands higher than 3.5m from the pavilion floor must be set back from the neighboring stand. If it includes corners or island ends, the stand must comply with the setback table, even if it is made of transparent glass.

HIGH FLOORS

Floors raised by wooden or modular tabling must include a 1m wide access ramp for people with special needs, in accordance with the ABNT standard (NBR - 9050). The ramp must be within the limits of the stand area. Stands smaller than 20m² and without a ramp must also guarantee access for the disabled.

 

FLOORS IN A STAND WITH HYDRAULICS

If you need a plumbing point in your stand, you must build a raised floor 10 cm above the ground.

GLASS WALLS

Walls assembled with single-glazed panels must have a maximum height of 3.5m and contain safety signs. Above this height, only glass panels with insulin film or polycarbonate, acrylic, laminated or tempered glass panels will be allowed. It is strictly forbidden to drill holes or apply paints, glues or other materials to the walls, floors, installations or structures of the halls, as well as to lean against or use any kind of support material on walls, columns or doors.

STAND BOUNDARIES

Traffic routes, neighboring areas and unbuilt areas may not be used to store materials, tools or products used on the stand.

AERIAL ELEMENTS

Air elements are allowed in all pavilions. To contract air points, please contact Center Norte's official supplier, JA Promoções: Email: cabosaereos@japromocoes.com.br - Phone: (11) 98130-7734 / (11)3865-1197 Value per point R$ 376.20/point for assemblers and exhibitors. Weight capacity per point: 50kg per point.

OVERHANGING ELEMENTS AND VERTICAL PROJECTION OF THE STAND

Only overhanging elements that project inside the stand will be allowed. Swings over common areas or neighboring stands are prohibited.

CABLES

Only overhanging elements that project inside the stand will be allowed. Swings over common areas or neighboring stands are prohibited.